EN50131 GRADE 3 COMPLIANT ALARM CONTROL PANEL MAIN BOARD, WITH 16 UP TO 64 ZONES AND OUTPUTS Due to their full compliance with the requirements ofEN50131 Grade 3, the INTEGRA Plus control units are perfectly fitfor implementation of advanced security systems at locations withparticularly high risk of burglary, such as banks, jewellery stores orpublic utility facilities. The control units are characterised by extendedfunctionality, due to which they can be used for implementation ofaccess control systems or even intelligent building solutions. full compliance with EN50131 series of standards for Grade 3 equipment built–in advanced 2 A+1.5 A power supply with extended autodiagnostics up to 64zones with programmable EOL value and support for 3 EOL configuration (only mainboard zones) USB port for programming via PC up to 32 partitions, 8 tenants up to 64 fully programmable outputs dedicated buses for communication with keypads and expansion modules system operation via LCD keypads, partition keypads, remote control keyfobs or proximity cards remote system operation with PC, smartphone or voice–guided telephone menu 64 independent timers for automatic control access control and home automation features non–volatile event log with 5631 entries, with on–line printing support support for 192+8+1 user codes firmware upgrades via PC option of not reporting server SATEL failure to the control panel (INTEGRA Firmware 1.16 or newer) The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu INTRUDER ALARMS Alarm control panels / INTEGRA / PCB INTRUDER ALARMS Alarm control panels / INTEGRA / PCB TECHNICAL DATA Installer-defined text messaged 64 Extender circuits up to 64 Environmental class according to EN50130-5 II Voice messages 16 Communication buses 1+2 Maximum number of programmable inputs 64 Maximum number of programmable outputs 64 Maximum humidity 93±3% Maximum current consumption from the battery 200 mA Maximum current consumption from the 230V network 400 mA Maximum battery charging current 1500 mA Manipulators up to 8 Weight 320 g Battery cut-off voltage (±10%) 10,5 V Power supply output voltage 10,5…14 V DC Supply voltage (±15%) 20 V AC, 50-60 Hz Battery failure voltage threshold (±10%) 11 V Telephone numbers for notification (voice/PAGER + SMS) 16+16 Carrying capacity of the +EX1 and +EX2 outputs (±10%) 3000 mA Low current programmable outputs rating 50 mA High current programmable outputs rating 3000 mA Carrying capacity of the +KPD output (±10%) 3000 mA Event log 5631 Objects 8 Current consumption from the 230V network in standby 135 mA Current consumption from battery - standby 130 mA Security grade according to EN 50131 Grade 3 Partitions 32 Timers 64 Users + Administrators 192 + 8 Programmable wired inputs 16 Power supply current efficiency (supplying devices + charging batteries) 2000 + 1500 mA Programmable wired outputs 16 Supplying outputs 3 Board dimensions 264 x 134 mm Operating temperature range -10…+55 °C Recommended transformer type 75 VA he actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu
ما آماده پاسخگويي در تمام زمينه هاي مربوط به فعاليت های گروه فنی مهندسی پارس ایمن لاریچه هستيم. لطفا جهت ارتباط با ما، درخواست خود را از طریق ایمیل برای ما ارسال فرمایید و یا از طریق تلفن با ما ارتباط برقرار کنید.