EN50131 GRADE 3 COMPLIANT ALARM CONTROL PANEL MAIN BOARD, WITH 16
UP TO 128 ZONES AND OUTPUTS
Due to their full compliance with the requirements ofEN50131 Grade 3, the INTEGRA Plus control units are perfectly fitfor implementation of advanced security systems at locations withparticularly high risk of burglary, such as banks, jewellery stores orpublic utility facilities. The control units are characterised by extendedfunctionality, due to which they can be used for implementation ofaccess control systems or even intelligent building solutions.
full compliance with EN50131 series of standards for Grade
3 equipment
built–in advanced 2 A+1.5 A power supply with
extended autodiagnostics
up to 128 zones with programmable EOL value and support
for 3 EOL configuration (only mainboard zones)
USB port for programming via PC
up to 32 partitions, 8 tenants
up to 128 fully programmable outputs
dedicated buses for communication with keypads and
expansion modules
system operation via LCD keypads, partition keypads, remote control keyfobs or proximity cards
remote system operation with PC, smartphone or voice–guided telephone menu
64 independent timers for automatic control
access control and home automation features
non–volatile event log with 22,527 entries, with on–line printing support
support for 240+8+1 user codes
firmware upgrades via PC
option of not reporting server SATEL failure to the control panel (INTEGRA Firmware 1.16 or newer)
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu
INTRUDER ALARMS
Alarm control panels / INTEGRA / PCB
INTRUDER ALARMS
Alarm control panels / INTEGRA / PCB
TECHNICAL DATA
Voice messages 32
Low current programmable outputs rating 50 mA
High current programmable outputs rating 3000 mA
Event log 22527
Objects 8
Partitions 32
Timers 64
Board dimensions 264 x 134 mm
Operating temperature range -10…+55 °C
Supply voltage (±15%) 20 V AC, 50-60 Hz
Weight 320 g
Maximum humidity 93±3%
Current consumption from battery - standby 130 mA
Recommended transformer type 75 VA
Battery failure voltage threshold (±10%) 11 V
Battery cut-off voltage (±10%) 10,5 V
Environmental class according to EN50130-5 II
Current consumption from the 230V network in standby 135 mA
Maximum current consumption from the 230V network 400 mA
Users + Administrators 240 + 8
Maximum current consumption from the battery 200 mA
Maximum battery charging current 1500 mA
Power supply current efficiency (supplying devices + charging batteries) 2000 + 1500 mA
Power supply output voltage 10,5…14 V DC
Carrying capacity of the +KPD output (±10%) 3000 mA
Carrying capacity of the +EX1 and +EX2 outputs (±10%) 3000 mA
Programmable wired inputs 16
Maximum number of programmable inputs 128
Programmable wired outputs 16
Maximum number of programmable outputs 128
Supplying outputs 3
Communication buses 1 + 2
Manipulators up to 8
Extender circuits up to 64
Telephone numbers for notification (voice/PAGER + SMS) 16 + 16
Installer-defined text messaged 64
Security grade according to EN 50131 Grade 3