The VERSA IP control panel is designed for protection of small andmedium–sized premises. It allows you to create a wired or wirelesssystem, as well as a hybrid one, which combines both these kinds ofsystem. It is compatible with ACU–120 and ACU–270 controllers,
which offer an excellent operating range for the ABAX family devices
– even up to 500 m in the open.
The VERSA IP is the only solution that combines features that werepreviously only available by using several separate devices. ETHM,
INT–VG and INT–AV modules as well PSTN dialer are integrated onits mainboard. As a result, the VERSA IP control panel enablescommunication via two channels: Ethernet and PSTN, thus ensuringeffective transfer of information.
EN50131 Grade 2 compliance
4 programmable wired zones:
support for NO and NC type detectors, and rollershutter and vibration detectors
support for EOL and 2EOL configurationadditional tamper input, NC type5 programmable wired outputs:
2 high–current outputs2 high–current outputs, OC type1 relay output3 power outputsoutput for connecting dedicated enclosure–mounted piezoelectric transducer (acoustic signaling)
maximum number of programmable zones: 30maximum number of programmable outputs: 12system subdivision into 2 partitions:
each zone can be assigned to two partitions
system control by means of:
LCD or LED keypadsVERSA–LCDM–WRL wireless keypadsINT–TSG, INT–TSH touchscreen keypadsproximity cardsremote control keyfobs
integrated PSTN module to enable:
reporting (SIA, ContactID, etc.)
voice messaging (8 numbers, 16 messages)
remote programming (300 bps modem) with DLOADX programbuilt–in ETHM module to enable:
e–mail messagingcontrol by means of VERSA CONTROL application offering PUSH notificationsreporting to monitoring stationprogramming with DLOADX programbuilt–in voice module:
nearly 13 minutes for messages to be used in voice menu
over 4 minutes for 16 telephone notification messages (with message duration up to 16 seconds)
built–in USB–HID socket
memory of 2047 events
capability to handle 30 users and assign to each of them:
code proximity card
keyfob
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu
INTRUDER ALARMS
Alarm control panels / VERSA / PCB
INTRUDER ALARMS
Alarm control panels / VERSA / PCB
4 timers to enable automatic:
arming/disarming partitionscontrol of outputs (turning light ON/OFF, watering garden, etc.)
plug–in terminal blocks
option of not reporting server SATEL failure to the control panel (VERSA Firmware 1.08 or newer)
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu
INTRUDER ALARMS
Alarm control panels / VERSA / PCB
INTRUDER ALARMS
Alarm control panels / VERSA / PCB
TECHNICAL DATA
Voice messages 16
Low current programmable outputs rating 50 / 12 VDC mA
Event log 2047
Partitions 2
Timers 4
Power supply rating 2 A
Enclosure dimensions 266 x 286 x 100 mm
Board dimensions 173 x 105 mm
Operating temperature range -10…+55 °C
Supply voltage (±15%) 18 V AC, 50-60 Hz
Maximum humidity 93±3%
Current consumption from 230 V mains - standby 120 mA
Current consumption from battery - standby 160 mA
Battery failure voltage threshold (±10%) 11 V
Battery cut-off voltage (±10%) 10,5 V
Environmental class according to EN50130-5 II
Maximum current consumption from the 230V network 160 mA
Maximum current consumption from the battery 200 mA
Programmable wired inputs 4
Maximum number of programmable inputs 30
Programmable wired outputs 5
Maximum number of programmable outputs 12
Supplying outputs 3
Communication buses 1
Manipulators up to 6
Security grade according to EN 50131 Grade 2
Current-carrying capacity, AUX output 500 / 12 V DC
Recommended transformer 40 VA
Mass (incl. enclosure and accessories) 1220 g
Users 30
Notification e-mail addresses 8
Text messages 64
Current-carrying capacity of +VR output 200 / 12 V DC
Current-carrying capacity of KPD output 500 / 12 V DC
Current-carrying capacity of programmable relay output 1000 / 24 V DC mA
Current-carrying capacity of programmable high-current outputs 1100 / 12 VDC mA
Output voltage range 10,5 V…14 V DC
Battery charging current 800 mA
Power supply output voltage 12 V DC ±15%
Telephone numbers for notification 8
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu